Stone Strong Systems Field Construction Manual introduces the construction requirements of Stone Strong Systems precast modular unit retaining wall system
This manual provides general information and proper techniques for building Stone Strong Systems precast modular unit retaining walls. It outlines the responsibilities of dealers, engineers, and contractors, as well as requirements for materials, delivery, and storage. The document emphasizes the need for a thorough site review and adherence to contract documents and plans.
| Concrete compressive strength | minimum 28-day compressive strength of 4,000 psi |
|---|---|
| Entrained air content | between 5 and 7% |
| Reinforcing steel grade | Grade 60 |
| Minimum clear cover | 1½ inches |
| Wall base compressive strength | minimum 28-day compressive strength of 3,000 psi |
| Base compaction density | minimum of 95 percent of the maximum dry density |
| Geotextile tensile strength | minimum grab tensile strength of 120 pounds |
The contractor is solely responsible for safety.
The wall base shall consist of a lean concrete with a minimum 28-day compressive strength of 3,000 psi.
Recommended tools include an excavator, laser level, skid steer, front loader, shovels, compactor, brooms, spreader bar, pry bars, and chains.