E2 Systems BE 22/33 SKM Pneumatic Milling Unit User Manual

This manual introduces the basic structure, installation, use and maintenance of the BE 22 SKM / BE 33 SKM pneumatic milling unit.


E2 Systems BE 22/33 SKM Pneumatic Milling Unit User Manual - cover page
Brand
E2 Systems
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
424 KB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
7BE8199BA9349773CF4246952106D928

About this manual

The document provides instructions for the safe installation and commissioning of the BE 22 SKM and BE 33 SKM pneumatic milling units. It details security precautions, connection requirements including air supply specifications, and mounting procedures for both vertical and horizontal orientations.

Technical information includes performance data such as power output, speed ranges, torque values, and dimensional drawings. The manual also outlines a maintenance schedule ranging from daily checks to annual overhauls and lists spare parts with part numbers.

What's inside

  • Security
  • Description of the milling unit
  • Installation of the milling unit
  • Mounting of cutting tools
  • Maintenance instruction
  • Replacement of tool holder
  • Technical information
  • Spare parts list

Specifications

Working pressure range6-7 bar (85 — 100 Psi)
Ambient temperature+ 10° - +40° C (+50° - + 104° F.)
Sound level70 dB(A)
Spindle thread> 3/8" — 24 UNF
Air consumption (BE 22 SKM)< 0,3 Nm°/min (< 12 Cfm)
Air consumption (BE 33 SKM)< 0,5 Nm°/min (< 19 Cfm)
Spindle spacing (BE 22 SKM)Min. 45 mm
Spindle spacing (BE 33 SKM)Min. 50 mm

Frequently asked questions

What is the maximum operating pressure?

The maximum working pressure is 7 bar (101.5 Psi).

How often should the air motor be overhauled?

Overhauling and cleaning of the air motor should be performed every 12 months or after 1500 to 2000 working hours.

What type of lubrication is recommended?

A mineral-based lubrication oil with a viscosity between 50 and 300 cSt at the operating temperature is recommended.