This manual describes the maintenance and setup of the HPR 400P series Portable Acoustic Positioning System.
The document serves as a guide for trained maintenance technicians regarding the Kongsberg Simrad HPR 400 Portable system. It details the maintenance philosophy based on built-in test equipment (BITE) and Line Replaceable Units (LRU), instructing users to replace modules rather than repair internal circuitry.
The manual provides comprehensive instructions for installation, setup, and maintenance of various components including the HPR 400 Transceiver Unit, Operator Station, and multiple transducer types such as PMT 301, Standard MF/LF, and Dunking transducers. It also includes technical specifications, spare parts lists, and system drawings.
| Operating Temperature | -10°C to +55°C |
|---|---|
| Storage Temperature | -40°C to +70°C |
| Mains Supply | 230 Vac (110 Vac on request) |
| Medium Frequency Range | 21,000 Hz - 32,500 Hz |
| Low Frequency Range | 9,500 Hz - 15,750 Hz |
| SSBL Accuracy (Wide Beam) | ±80_ ≤ 2 % of slant range |
The maintenance technician is only expected to replace modules and units, relying on built-in test equipment (BITE) for diagnostics.
No. Detailed mechanical and electrical maintenance should be performed by a specialist engineer, while operators are expected to replace Line Replaceable Units (LRUs).