This manual describes the safe use of the TESSY software.
The TESSY 4.3 Safety Manual provides critical information for using the TESSY tool in safety-relevant environments. It details the core workflow, which includes test execution, evaluation, and report generation, and notes that this specific workflow is certified according to ISO 26262, IEC 61508, EN 50128, and IEC 62304. Users are advised to register for a safety customer e-mail list to receive updates on known problems and workarounds.
| Certification Standards | ISO 26262-08:2011, IEC 61508-3:2010, EN 50128, IEC 62304 |
|---|---|
| Tool Classification | T2 offline tool |
| Supported Language | ANSI compliant C code |
You must register for the safety customer e-mail-list by sending an email to [email protected] with the topic 'Known problems requested'.
No, the CTE is not part of the certified core workflow; it covers test preparation activities.
TESSY does not check any runtime behavior or timing constraints of the function under test.