This manual introduces the operation and maintenance of White Industries 1234XL 1090XL 1095XL, including setup, safety precautions, recovery and recycling, vacuuming, vacuum leak test, adding lubricant, charging the vehicle air conditioning system, charging virgin, charging recycled, sequential operation, topping off an air conditioning system, maintenance and operational tips, maintenance schedule, replacing the main filter core, check/replace vacuum pump oil, check/replace O-rings, check/replace hose depressors and gaskets, check/replace hose filter assemblies, error codes, and answers to frequently asked questions
This document serves as the Operations and Maintenance Manual for White Industries air conditioning service equipment, specifically covering models 1234XL, 1090XL, and 1095XL. It details the setup process, safety precautions regarding refrigerant handling, and step-by-step procedures for recovering and recycling refrigerant from vehicle air conditioning systems.
| Refrigerant Types Supported | R-12 and R134 (1234XL); R-134 Only (1090XL); R-12 Only (1095XL) |
|---|---|
| Warranty Period | One (1) year from date of purchase |
| Power Requirement | 110-volt grounded outlet |
| Extension Cord Gauge | 14 gauge or heavier |
| Vacuum Target | Six inches of mercury |
The machine must be operated by a technician certified in refrigerant recovery recycling.
Operators should always wear safety goggles to protect their eyes.
Inspect the unit's micron filters, depressors, gaskets, and valve cores, and ensure connections allow complete access to the system.