This manual is for Nivisys GCP-2 series laser pointers, including 50mw and 100mw models.
This document serves as the Operator Manual for the Nivisys GCP-2 Series Ground Commander Pointer. It provides instructions for the proper care and operation of the equipment, covering specific models such as the GCP-2/V1, GCP-2A/V2, and CP-2B variants.
The manual includes critical safety data regarding laser classes, power outputs, and hazard distances. It also defines the meaning of advisory statements like WARNING, CAUTION, and NOTE found throughout the text to ensure safe handling and mission effectiveness.
| Laser Power Output, High | 50mW, 100mW, 175mW |
|---|---|
| Laser Power Output, Low | 0.5mW |
| Laser Beam Divergence | 0.5mR, 0.3mR |
| Laser Safety Class, High | 3B |
| Laser Safety Class, Low | 3R |
| Nominal Ocular Hazard Distance (High) | 384ft, 544 ft, 709 ft |
| Laser Wavelength | 830-840 nm |
It highlights an operation or procedure which, if not strictly observed, could result in injury to or death of personnel.
It highlights an operation or procedure which, if not strictly observed, could result in damage to or destruction of equipment or loss of mission effectiveness.
It highlights an essential operation, procedure, condition, or statement.