This manual provides installation, operation and maintenance instructions for 4 inch submersible pumps.
The document serves as a comprehensive guide for the installation, operation, and maintenance of the CentriPro IM096R12 4-inch submersible pump. It covers critical safety instructions regarding electrical work and system pressure, along with detailed steps for typical installations involving piping, tanks, and control boxes.
| Minimum submergence for proper refill check valve operation | 5 feet |
|---|---|
| Maximum pressure rating warning | Do not over pressurize the tank, piping or system to a pressure higher than the tank's maximum pressure rating. |
| Minimum flow rate for 4" motors >= 2 HP | .25 ft/sec. or 7.62 cm/sec. |
| Minimum flow in GPM per well diameter | 1.2 GPM/4" |
| Pressure relief valve requirement threshold | 75 PSI or 100 psi |
All electrical work must be performed by a qualified technician.
Installations must follow the National Electrical Code (NEC), Canadian Electrical Code, and all local codes.
The pressure switch should be located within 4 feet of the tank to prevent switch chatter.
Adjust the tank pre-charge to 2 PSI below the system cut-in pressure setting.