Laing Thermotech Series E1 and E3 Instant Hot Water Recirculating Systems Installation Operation and Service Instruction

This is an instruction manual that details the features, functions, and usage of the Laing Thermotech Series E1 and E3 instant hot water recirculating systems.


Laing Thermotech Series E1 and E3 Instant Hot Water Recirculating Systems Installation Operation and Service Instruction - cover page
Brand
Laing
Category

Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
910 KB
Published
15 October, 2023
Updated
15 October, 2023
MD5 checksum
CC269CB226295FBA0FBA37E8D13FA1E7

About this manual

This manual covers the installation, operation, and servicing of Laing Thermotech Series E1 and E3 Instant Hot Water Recirculating Systems. It includes safety warnings regarding electrical shock and hot water leakage, as well as specific recommendations for pump selection based on pipe loop length (up to 250 ft for E1 and up to 700 or 1000 ft for E3).

What's inside

  • About Recirculation Systems
  • Air in the System
  • Water Pressure
  • Multiple Floors
  • Oversized Pumps
  • Pump Selection Guide
  • Installation and Start Up
  • Adjustable Thermostat Option
  • Wiring Instructions

Specifications

E1 Series Pipe Loop Lengthup to 250 ft (76 M)
E3 Series Pipe Loop Lengthup to 700 or 1000 ft. (213-304 M)
Minimum Wire Temperature Rating221°F (105°C)
Thermostat Set Point Range68°F to 158°F (20°C to 70°C)
Thermostat Hysteresismore than 10°F (6°C) below the Set Point
Minimum Electrical Wire Size14 AWG copper electrical wire

Frequently asked questions

What is the maximum pipe loop length for the E1 Series?

The E1 Series is designed to handle recirculation requirements for residences with a pipe loop up to 250 ft (76 M).

What is the maximum pipe loop length for the E3 Series?

The E3 Series pumps can handle circulation requirements for systems with pipe loop runs up to 700 or 1000 ft (213-304 M).

What is the recommended minimum water pressure for these systems?

A system pressure of at least 35 psi (241 kPa) is generally required; below this, air may accumulate in the lines.

Can these pumps be installed above the water heater?

No, the pump must always be installed below the water level of the water heater so that flow is upward or horizontal.