GT IRRI-GATOR Self-Priming Centrifugal Pumps Instruction Manual

This is the instruction manual for GT IRRI-GATOR SELF-PRIMING CENTRIFUGAL PUMPS INSTRUCTION MANUAL, which mainly introduces the product's safety instructions, description and specifications, engineering data, installation, maintenance, etc.


GT IRRI-GATOR Self-Priming Centrifugal Pumps Instruction Manual - cover page
Brand
GT IRRI-GATOR
Category
AC Motors
Document type
User Manual
Language
English
Pages
24
File format
PDF
File size
1 MB
Published
15 October, 2023
Updated
15 October, 2023
MD5 checksum
0DF0E2A3DC3FEDCBF1E90A4D88480182

About this manual

The GT IRRI-GATOR Self-Priming Centrifugal Pumps are end suction, single stage units designed for lawn sprinkling, HVAC systems, and general water transfer. The casing is constructed of cast iron with tapped openings for a vacuum gauge and casing drain. Standard motors are NEMA standard, 3500 RPM, with an open drip proof enclosure. Impellers are enclosed design, glass filled NorylTM, and are threaded directly on the motor shaft.

What's inside

  • Safety Instructions
  • Description and Specifications
  • Engineering Data
  • Piping – Suction
  • Piping – Discharge
  • Wiring and Grounding
  • Operation
  • Maintenance
  • Disassembly
  • Trouble Shooting

Specifications

Casing MaterialCast iron
Impeller MaterialGlass filled NorylTM
Motor RPM3500 RPM
Maximum Liquid Temperature160ºF (71ºC)
Maximum Starts per Hour20
Total Suction Lift25 feet of head

Frequently asked questions

What is the correct rotation for the pump?

The correct rotation is right hand, CLOCKWISE when viewed from the motor end.

Is lubrication required for the pump?

No lubrication is required on the pump itself; motor lubrication should follow the manufacturer's instructions.

What should be done if the motor is not running?

Check if the motor thermal protector tripped, if the circuit breaker is open or fuse is blown, if the impeller is binding, or if the motor is improperly wired.