This manual describes the installation, operation and maintenance of the SOLARAYC domestic solar water heating system.
The SunEarth SolaRay domestic solar water heating system is a forced circulation system designed to meet SRCC OG-300 certification requirements. It utilizes a mechanical pump to circulate a non-toxic propylene glycol heat transfer fluid (HTF) to protect the system from freezing down to -60°F (-51°C). The system is intended for installation by licensed professional contractors in accordance with applicable codes and regulations.
Key components of the system include the SunEarth solar collector, a solar storage tank with an integral heat exchanger, a circulation pump, a differential temperature controller, an expansion tank, a pressure gauge, and a mixing valve. The manual covers system description, installation requirements, startup procedures, operation modes, maintenance, troubleshooting, and component life estimates.
| Freeze Protection Limit | -60°F (-51°C) |
|---|---|
| Recommended Freeze Protection Fluid | Dow Chemical "Dowfrost HD" propylene glycol |
| Factory Thermostat Setting | 120°F (50°C) |
The system should not be installed in areas where ambient air temperatures drop below -60°F (-51°C).
No, unauthorized fluid substitutions can void warranties and threaten safety; only Dow Chemical "Dowfrost HD" propylene glycol is specified.
Installation must be executed by properly licensed and experienced professional contractors in accordance with SRCC Standard OG-300.