This document is the instruction manual for SENSIT® HXG-2d combustible gas detector.
The SENSIT® HXG-2d is a portable combustible gas detector designed to measure concentrations of gases such as Methane, Butane, Propane, and Natural Gas in both PPM and %LEL ranges. It features an advanced low power semiconductor sensor, a graphic display with electronic tick control for leak location, and audible/visual alarms. The device is intrinsically safe for use in Class I, Groups C and D, T3 hazardous locations when used with approved batteries.
| Resolution (PPM) | 10ppm |
|---|---|
| Range (LEL) | 0-100%LEL |
| Accuracy | ±10% |
| Size | 254 x 76 x 41 mm |
| Weight | 544 g |
| Operational Temp | -20° to 40° C |
It is suitable for combustible gases such as Methane, Butane, Propane and Natural Gas.
The instrument requires Duracell PROCELL, Type PC1400 Alkaline Batteries.
Alkaline batteries provide approximately 50 hours of continuous use.