FAAC 844 Sliding Gate Operator Installation Guide

This manual provides detailed instructions on how to install the 844 electric sliding gate


FAAC 844 Sliding Gate Operator Installation Guide - cover page
Brand
FAAC
Category
Industrial Robot
Document type
Installation Guide
Language
English
Pages
21
File format
PDF
File size
1.5 MB
Published
13 October, 2023
Updated
13 October, 2023
MD5 checksum
90C18593CE69E26590C76B10F24B5A00

About this manual

This document provides installation instructions for the FAAC mod. 844 automated system for sliding gates, which is an electro-mechanical operator transmitting motion to the sliding gate via a rack or chain pinion. The system includes a gearmotor equipped with a mechanical clutch and an electronic device for adjustable anti-crushing safety. It is designed to control access of vehicles and ensures the gate is mechanically locked when the motor is not operating.

The guide covers preliminary checks for the gate structure and soil stability, masonry work for the foundation plate, mechanical installation of the operator, and installation of the steel rack (both for welding and screwing methods). It also details the electrical equipment setup and safety warnings for the installer.

What's inside

  • Warnings for the Installer
  • Description and Technical Specifications
  • Dimensions
  • Installation of the Automated System
  • Mechanical Installation
  • Installing the Rack
  • Electrical Equipment
  • Preliminary Checks

Specifications

Power supply230V +6% - 10% 50-60Hz
Absorbed power660 W
Reduction ratio1:30
Max. thrust110 daN (Z16) - 88 daN (Z20)
Max. Torque35 Nm
Winding thermal protection120°C
Use frequency70%
Oil quantity18 cc
Operating ambient temperature-20°C to +55°C
Gearmotor weight145 Kg
Protection classIP 44
Gate max. weight1800 Kg (Z16) - 1000 Kg (Z20)
Gate speed9.5 m/min (Z16) - 12.2 m/min (Z20)
Gate max. length40 m (Z16) - 50 m (Z20)
RPM1400
Absorbed current3.5 A
Starting capacitor36 uF

Frequently asked questions

What standards must the installation conform to?

The installation must conform to Standards EN 12453 and EN 12445.

How often should the efficiency of the system be checked?

The efficiency of the system should be checked at least every 6 months.

What is the maximum gate weight for the Z16 model?

The maximum gate weight for the Z16 model is 1800 Kg.