This user manual introduces the use and programming methods of the California Instruments 801RP/1251RP series AC power source.
The document serves as a User and Programming Manual for the California Instruments 801RP and 1251RP Series AC Power Sources. It provides comprehensive instructions for installation, unpacking, and front panel operation, including guided tours of the controls. The manual details the principles of operation, covering the power factor correction module, DC-DC converter, and oscillator control board.
| Output Power | 800VA or 1250VA |
|---|---|
| Output Voltage Range | 0-135V or 0-270V |
| Frequency Range | 16 Hz to 500 Hz |
| Max Output Current (1251RP) | 9.2 amps @ 135V, 4.6 amps @ 270V |
| Max Output Current (801RP) | 6 amps @ 135V, 3 amps @ 270V |
| Input Voltage | 100 to 240 VAC |
| Input Frequency | 50 Hz or 60 Hz |
The maximum output current for the 1251RP is 9.2 amps on the 135 volts range and 4.6 amps on the 270 volts range.
The maximum output current for the 801RP is 6 amps on the 135 volt range and 3 amps on the 270 volts range.
The output has two voltage ranges of 0-135V or 0-270V.
The unit requires a universal nominal input from 100 volts to 240 volts.