This manual provides operating instructions, maintenance information and safety instructions for the E1M18 and E2M18 rotary vacuum pumps.
This manual provides comprehensive instructions for the BOC Edwards E1M18 and E2M18 rotary vacuum pumps, covering installation, operation, maintenance, and troubleshooting. It includes specific guidance on electrical connections for single-phase and three-phase motors, as well as safety procedures for handling flammable materials in accordance with the ATEX directive.
The document details the maintenance plan, including oil checks and replacements, filter cleaning, and motor inspections. It also lists available spare parts and accessories with item numbers and provides a fault-finding guide for common issues such as failure to start, noise, or poor pumping speed.
| Voltage (Single-phase) | 100/200 V, 50 Hz or 100-105/200-210 V, 60 Hz |
|---|---|
| Voltage (Single-phase) | 115/230 V, 60 Hz |
| Voltage (Single-phase) | 220-240 V, 50 Hz or 230-240 V, 60 Hz |
| Voltage (Three-phase) | 200-230/380-460 V, 50/60 Hz |
| Compliance Standard | EN ISO 12100-2: 2003 |
| Compliance Standard | EN 61010-1: 2001 |
Users must not allow air to enter the equipment and must ensure the system is leak tight.
This is listed as a fault finding issue where the pump fails to reach ultimate vacuum.