The features and characteristics of DIGIFORCE® 9310 measuring instrument are introduced, including measurement methods, measurement functions, evaluation methods, window techniques, trend tracking, etc.
This document is the operation manual for the Burster DIGIFORCE 9310, a press fit controller used for process monitoring. It details preparations for service including unpacking, mounting requirements, and power connection specifications.
The guide explains the device concept, measuring methods, and various evaluation windows such as thread-in, pass, block, and envelope techniques. It provides instructions on operating the front keys, navigating menus, configuring channels for strain gage or piezo sensors, and setting up measurement programs with specific reference points.
| Supply voltage range | 90...264V/47-63Hz |
|---|---|
| Power consumption | approx. 10 VA |
| Operating temperature range | 5 - 40° Celsius |
| Storage temperature range | 0...60°C |
The instrument features RS232, RS485, Ethernet, and PROFIBUS interfaces.
The device must operate within a temperature range of 5 to 40 degrees Celsius.
The supply voltage must be between 90 and 264 volts at a frequency of 47 to 63 Hz.
The instrument requires a fuse with a rating of 0.16 AT.