EcoFasten ClickFit Installation Guide v2.6

This document describes the installation of the ClickFit mounting system for photovoltaic modules on steep-slope roofs.


EcoFasten ClickFit Installation Guide v2.6 - cover page
Brand
EcoFasten
Document type
Installation Guide
Language
English
Pages
35
File format
PDF
File size
2.8 MB
Published
12 October, 2023
Updated
12 October, 2023
MD5 checksum
2637FB6F60C5C03D46149C2D10B179D9

About this manual

This document provides an installation guide for the EcoFasten ClickFit mounting system, designed for photovoltaic modules on steep-slope roofs. The system features a tool-free Click-In Rail assembly that connects to various roof attachments without fasteners or tools, utilizing robust aluminum and coated steel materials.

The guide covers the entire installation process, including pre-installation planning, rail splicing, attaching flashing and L-feet (or tile hooks), mounting rails, securing modules with clamps, and grounding. It includes specific torque specifications for components like mid-clamps and end-clamps, as well as compatibility information for alternate components.

What's inside

  • Features & Benefits
  • Introduction
  • Overview
  • Components
  • Ratings
  • Array Layout
  • Installation Steps
  • Grounding
  • Accessories
  • Module List

Specifications

Max System Voltage1500 VDC
Max Fuse Rating40A
Certification StandardUL STD 2703
Warranty Period25 Year
Roof Pitch Range2:12 – 12:12
Max Module Size25.6 sqft
Mid-Clamp Torque144 in-lb
End-Clamp Torque96 in-lb

Frequently asked questions

What is the maximum system voltage rating?

The system has a maximum system voltage rating of 1500 VDC.

What is the maximum system voltage for the ClickFit system?

The maximum system voltage is 1500 VDC.

What is the required torque for the Mid-Clamp?

The Mid-Clamp must be torqued to 144 in-lbs.

How deep should the flashing be pushed into the shingles?

The flashing must be pushed to the third-course of shingle.