This manual introduces installation, setup and commissioning of HD700 Drive, also troubleshooting and maintenance. This HD700 User Manual is for easy and efficient operating.
The document serves as a comprehensive guide for the HEDY HD700 AC Drive, providing instructions on installation, cabling, and electrical connections. It details the mechanical dimensions and mounting procedures required for safe setup in industrial environments.
The manual further explains drive operation through keypad control and terminal configurations, including parameter settings for various control modes such as V/F and Vector control. It also includes troubleshooting guides for faults and alarms, routine maintenance schedules, and specific technical specifications for different power ratings.
| Power range | 0.4kW~500kW |
|---|---|
| Input voltage | 220V, 380V, 690V |
| Input frequency | 48Hz~62Hz |
| Output frequency range | 0Hz~300Hz |
| Overload capacity (E, G type) | 150% rated output current for 1 minute |
| Overload capacity (P type) | 110% rated output current for 1 minute |
The drive should ONLY be installed by a qualified electrician.
Wait at least 10 minutes to allow intermediate circuit capacitors to discharge before removing the cover.
No, it is not a field repairable unit; contact the factory or an Authorized Service Center for replacement.