This document is the user manual for the BFT-48 transmitter. It includes safety information, installation instructions, and initial start-up.
The BFT-48 is a single or dual channel fixed-point monitor designed for continuous monitoring of hazardous gases in the workplace. It supports various input types, including electrochemical toxic/oxygen sensors, catalytic bead combustible sensors, MOS solid-state sensors, and millivolt/volt/4-20mA inputs. The device features a standard 4-20 mA output signal and offers options for alarm relays and RS-485 Modbus communication.
| Input Types | Electrochemical toxic / oxygen sensors, catalytic bead combustible sensors, MOS solid-state sensors, millivolts, volt and 4-20mA inputs |
|---|---|
| Output Signal | Standard 4-20 mA |
| Certification | CSA certified for Division 1 & 2 hazardous area installations |
| Calibration Schedule | At least every 90 days |
Users should calibrate with a known target gas at start-up and check on a regular schedule of at least every 90 days.
No, the equipment must be operated and serviced by qualified personnel only.
Yes, the BFT-48 is designed as a single or dual channel fixed-point monitor.