User Manual Interface for connecting up to 31 SIKO devices with RS485 interface to Profibus DP IF09P/1

This document provides a user interface for connecting up to 31 SIKO devices with RS485 interface to the Profibus DP IF09P/1 interface. The document includes general information, technical data, and operation instructions.


User Manual Interface for connecting up to 31 SIKO devices with RS485 interface to Profibus DP IF09P/1 - cover page
Brand
SIKO
Document type
User Manual
Language
English
Pages
51
File format
PDF
File size
992 KB
Published
17 February, 2023
Updated
28 September, 2023
MD5 checksum
B29F341E8EF2598B38C060E4698756A9

About this manual

The SIKO IF09P/1 is a PROFIBUS-DP gateway designed to couple SIKO position encoders using SN3 or SN4 protocols with a PROFIBUS control system. It allows the gathering and transfer of position and parameterization data from up to 31 connected devices to a PLC, such as a Siemens S7 controller.

The device features an integrated keyboard and a 5-digit display for comfortable configuration and diagnosis without external tools. It supports various baud rates on both the Profibus side (up to 12 Mbit/s) and the encoder interface side (SN3 at 19.2kBit/s or SN4 at 115.2kBit/s). The manual details technical specifications, connection diagrams, command lists for parameterization, and troubleshooting procedures.

What's inside

  • General Information
  • Technical Data
  • Functioning
  • Operation
  • Protocol Setting
  • Configuration
  • Command List
  • Troubleshooting

Specifications

Max. connected devices31
Power supply voltage24VDC +/- 20%
Power inputapprox. 1.3W
SN3 Bit rate19.2kBit/s
Profibus bit rate range9.6 Kbit/s to 12 Mbit/s

Frequently asked questions

What is the maximum number of devices that can be connected?

The IF09P/1 gateway supports a maximum of 31 devices with SN3 or SN4 protocols.

Can the device operate with both SN3 and SN4 encoders simultaneously?

No, mixed operation of SIKONETZ4 (SN4) and SIKONETZ3 (SN3) instruments is not possible.

What functional building block is required for Siemens S7 users?

Users require the functional building blocks SFC14 „DPRD_DAT“ or SFC15 „DPWR_DAT“ to enable consistent reading and writing of data.