Magnetek HPV900 AF Drive PM Motor Installation Manual

This document describes how to install the Magnetek HPV900AF Drive PM Motor


Magnetek HPV900 AF Drive PM Motor Installation Manual - cover page
Brand
Magnetek
Document type
Installation Guide
Language
English
Pages
13
File format
PDF
File size
1.1 MB
Published
30 December, 2022
Updated
29 September, 2023
MD5 checksum
46FADE72CD0EB606CD499D6BA875BCBB

About this manual

The document serves as a startup guide for the Magnetek HPV900 AF Drive when paired with a PM motor. It covers essential pre-installation steps such as equipment verification against job specifications and establishing proper controller grounding to prevent noise issues.

The guide details wiring procedures for main power, brakes, motor leads, encoders, and proximity sensors. It includes step-by-step instructions for powering up the system, performing final setup configurations via the LCD menu (including bypassing term limits), executing auto-tuning functions for encoder and motor alignment, and verifying proper operation.

What's inside

  • Equipment Verification
  • Controller Grounding Requirements
  • Wiring Instructions
  • Powering Up
  • Final Setup Configuration
  • Auto Tuning Procedures
  • Operation Verification
  • Troubleshooting

Specifications

Drive ModelHPV900 AF

Frequently asked questions

What is required for proper controller grounding?

All grounds, including building, motor, transformer, and filter grounds, must land at a common ground bus terminal connection to prevent ground loops.

How do you correct an Encoder fault?

Check for a solid shield-to-ground connection, verify correct wire colors, ensure C1 Encoder Select is set to Axial Flux, and swap A+/A- on terminal TB2.

What causes Setup Fault One?

It occurs when the HPV is programmed with motor data (A5) that conflicts with the drive software.

Download PDF (1.1 MB)