This document is a user manual for the U-SIN-P260G-SCN2 gas cylinder level transmitter produced by Hangzhou Sinomeasure Automation Technology Co., Ltd. The document provides information on the product's features, wiring methods, setup methods, operation methods, and troubleshooting methods. It also mentions that the product is prohibited from being used in explosive environments.
The Sinomeasure U-SIN-P260G-SCN2 is a gas cylinder level transmitter designed to measure liquid levels in high-temperature media. It operates by compressing air within an internal gas cylinder, transmitting pressure via a capillary tube to a sensitive element that does not directly contact the medium. This design allows for use in environments with temperatures up to 200°C. This manual is written in Chinese.
| Power Supply | 4-20mA (18-36V); 4-20mA with display (12-36V); 0-5V, 0-10V (12-32V) |
|---|---|
| Output Signal | 4~20mA; 0~5V; 0-10V |
| Accuracy | 0.5 grade (Class) |
| Measurement Range | 0m~1m...10m |
| Pressure Type | Gauge Pressure |
| Operating Temperature | -20°C to 85°C |
| Medium Temperature | -40°C to 200°C |
| Protection Rating | IP68 |
No, the product is prohibited from use in explosion-proof scenarios.
Remove the gas cylinder and drain the water inside the capillary tube to restore accuracy.
All non-customized products are guaranteed to be returned or exchanged within 7 days.