This document provides the operator's manual for ARV-570 and ARV-1230. These merchandisers are manufactured to meet ANSI / National Sanitation Foundation (NSF®) Standard #7 Type II requirements, and proper installation is required to maintain certification. The equipment is intended for the storage and display of nonpotentially hazardous, bottled or canned products in an 80°F / 55%RH ambient application. The document also includes contact information and location requirements.
This operator’s manual covers proper installation, electrical requirements, ventilation, and safety guidelines for the ARV-570 and ARV-1230 Chill Chambers. It explains the dedicated circuit specifications, minimum wire gauge, and required 5‑inch ventilation space, as well as procedures for uncrating, leveling, and inspecting the units.
The guide also details shelf installation, door‑torque adjustment, and programming of the Safe‑NET controller, including clock setting and pass‑code protected functions. Warranty information and auxiliary receptacle usage are included at the end of the document.
| Electrical circuit for ARV-570 | Dedicated 15 A circuit, NEMA 5‑15P |
|---|---|
| Minimum wire gauge | 12 AWG |
| Required ventilation | 5 inches (13 cm) on all sides |
| Shelf configuration – ARV-570 | Four rows of gravity‑feed shelves for 16 oz aluminum bottles |
| Shelf configuration – ARV-1230 | Four rows of flat‑wire shelves for 16 oz aluminum bottles or five rows for PET bottles |
| Auxiliary receptacle fuse – ARV-570 | 3 A fuse |
| Auxiliary receptacle fuse – ARV-1230 | 1 A fuse |
It must be connected to a dedicated 15 A circuit with a grounded NEMA 5‑15P receptacle.
Open the door 45°, then loosen the lower support nut while holding the upper nut, rotate the upper nut to increase or decrease torque, and retighten the lower nut.
Press SELECT until CLOC appears, then use the UP and DOWN buttons to set minutes and hours, confirming each with SELECT.
A 1 A fuse is required for the auxiliary 110 V receptacle on the ARV-1230.