Hussmann ARV-570 & ARV-1230 Chill Chamber Operator’s Manual

This document provides the operator's manual for ARV-570 and ARV-1230. These merchandisers are manufactured to meet ANSI / National Sanitation Foundation (NSF®) Standard #7 Type II requirements, and proper installation is required to maintain certification. The equipment is intended for the storage and display of nonpotentially hazardous, bottled or canned products in an 80°F / 55%RH ambient application. The document also includes contact information and location requirements.


Hussmann ARV-570 & ARV-1230 Chill Chamber Operator’s Manual - cover page
Brand
Hussmann
Document type
User Manual
Language
English
Pages
24
File format
PDF
File size
1.3 MB
Published
05 November, 2022
Updated
28 September, 2023
MD5 checksum
9FCDCBF0A9DDFE64C416847E99894F40

About this manual

This operator’s manual covers proper installation, electrical requirements, ventilation, and safety guidelines for the ARV-570 and ARV-1230 Chill Chambers. It explains the dedicated circuit specifications, minimum wire gauge, and required 5‑inch ventilation space, as well as procedures for uncrating, leveling, and inspecting the units.

The guide also details shelf installation, door‑torque adjustment, and programming of the Safe‑NET controller, including clock setting and pass‑code protected functions. Warranty information and auxiliary receptacle usage are included at the end of the document.

What's inside

  • Safety Guidelines
  • Electrical Requirements
  • Ventilation and Leveling
  • Shelf Installation
  • Door Torque Adjustment
  • Safe‑NET Controller Setup
  • Auxiliary Receptacle & Fuse
  • Warranty

Specifications

Electrical circuit for ARV-570Dedicated 15 A circuit, NEMA 5‑15P
Minimum wire gauge12 AWG
Required ventilation5 inches (13 cm) on all sides
Shelf configuration – ARV-570Four rows of gravity‑feed shelves for 16 oz aluminum bottles
Shelf configuration – ARV-1230Four rows of flat‑wire shelves for 16 oz aluminum bottles or five rows for PET bottles
Auxiliary receptacle fuse – ARV-5703 A fuse
Auxiliary receptacle fuse – ARV-12301 A fuse

Frequently asked questions

What electrical circuit is required for the ARV-570?

It must be connected to a dedicated 15 A circuit with a grounded NEMA 5‑15P receptacle.

How do I adjust the door torque on the Chill Chamber?

Open the door 45°, then loosen the lower support nut while holding the upper nut, rotate the upper nut to increase or decrease torque, and retighten the lower nut.

How is the Safe‑NET clock set?

Press SELECT until CLOC appears, then use the UP and DOWN buttons to set minutes and hours, confirming each with SELECT.

What fuse should be used for the auxiliary outlet on the ARV-1230?

A 1 A fuse is required for the auxiliary 110 V receptacle on the ARV-1230.