This document is a manual for the Magnum Board II swing operator, providing instructions for installation, operation, and maintenance of the product.
The Magnum Board II is a controller designed for use with GT-300, GT-400, and GT-500 swing operators in automatic entrance systems. The document serves as a wiring and adjustment guide, detailing electrical connections, fuse specifications, and potentiometer settings for proper operation.
| Compatible Operators | GT-300/400/500 |
|---|---|
| Fuse 1 Rating | 0.5 amp |
| Fuse 2 Rating | 3 amp, 250 volt |
| J2 Output Voltage | 24 VAC |
| J2 Max Current | 0.5 amp |
| GT-300/400 Opening Speed | 1.5 ~ 16 sec / 80 deg |
| GT-500 Opening Speed | 3.0 ~ 16 sec / 80 deg |
| Time Delay Max | 60 seconds |
The J2 connector provides a 24 VAC output to the actuating device.
The J2 circuitry is limited to a maximum current draw of 0.500 amps.
The STOP adjustment determines whether the door stops, slowly opens, or slowly closes when an object is sensed in the path of a moving door.