ILM ILM-300 Three-Door Interlock Controller User Manual

This document provides the user manual for ILM-300 three-door interlock controller, including its application, appearance dimensions, relay power, power input, and environmental temperature and humidity.


ILM ILM-300 Three-Door Interlock Controller User Manual - cover page
Brand
ILM
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
682 KB
Published
19 October, 2022
Updated
28 September, 2023
MD5 checksum
52BC4FC196FA4DB8D587C891C286DBBB

About this manual

The ILM-300 is a three-door interlock controller designed to manage exit mechanisms for three doors simultaneously. It supports both power-off exit and power-on exit types and features built-in relays that interlock the three doors, preventing any two doors from opening at the same time. The device is also adaptable for two-door applications by shorting the third relay group. This manual is written in Chinese.

What's inside

  • Overview
  • Specifications
  • Application Types
  • Wiring Diagrams
  • Signal Requirements
  • Installation Notes

Specifications

Dimensions73(L) x 63(W) mm
Relay Power3A@120VAC, 30VDC
Power Input12VDC or 24VDC
Operating Temperature-20~70°C
Relative Humidity0~95% non-condensing

Frequently asked questions

Can the ILM-300 be used for two doors?

Yes, it can be used for two-door applications by shorting the third relay group.

What are the supported power input voltages?

The controller accepts 12VDC or 24VDC power input.

How does the interlock mechanism work?

When any one door is opened, the other two doors cannot be opened until the first door is closed.