This document is an operation/technical manual for the IND560BC weighing batching controller. It introduces the product's overview, typical connected devices, measurement principles, technical specifications, operations, parameter settings, service and maintenance, installation, communication, and more.
The Mettler Toledo IND560BC is a detection and control terminal designed for dynamic metering and feed batching control systems. It features a menu-based interface and is widely applicable in industries such as metallurgy, power, ports, and chemicals for continuous feeding applications like belt and screw conveyors. The controller calculates flow and cumulative delivery by monitoring material weight and belt speed, adjusting the drive speed via closed-loop control to achieve target flow rates.
This manual guides users through installation, wiring, daily operation, parameter setting, debugging, routine maintenance, and fault diagnosis. It covers panel layout, status definitions, basic operations, configuration of parameters and communication ports, cleaning procedures, software upgrades, and troubleshooting for various alarm codes and system errors. This manual is written in Chinese.
| Dimensions (W×H×D) | 265 mm × 160 mm × 92 mm |
|---|---|
| Mounting Hole Size (W×H) | 243 mm × 127 mm |
| Operating Temperature | -10° ~ +40° C |
| Power Supply | 100–240 VAC, 49–61 Hz |
| Display | 128 × 64 VFD graphic dot matrix |
| Measurement Accuracy | 0.2% |
| Control Error | <0.03% |
Alarm code E1 indicates that the velocity has exceeded the set value, and the recommended measure is to increase the load.
Warning code W008 indicates that the belt has not started.