Henkel P3-emulpon 6771 Rust Inhibitor Emulsion Technical Manual

This document is a technical manual from Henkel Corporation for P3-emulpon 6771 rust inhibitor emulsion. The product is suitable for passivation and rust prevention of steel and cast iron materials before storage. It is easy to use and can be applied in immersion and spraying systems.


Henkel P3-emulpon 6771 Rust Inhibitor Emulsion Technical Manual - cover page
Brand
Henkel
Category
Other
Document type
Product Leaflet
Language
Chinese
Pages
2
File format
PDF
File size
183 KB
Published
19 September, 2022
Updated
28 September, 2023
MD5 checksum
550E17B8AD59F179AB0DD0C6A577EE28

About this manual

This document is a technical manual for Henkel P3-emulpon 6771, a rust inhibitor emulsion designed for passivation and rust protection of steel and cast iron materials prior to storage. It is specifically formulated for soft water applications and is suitable for spray and immersion processes at temperatures above 10°C. This manual is written in Chinese.

What's inside

  • Application Scope
  • Operating Process
  • Composition
  • Physical Properties
  • Concentration Testing
  • Foam Characteristics
  • Wastewater Treatment

Specifications

Temperature Range10-80°C
Processing Time0.5-3 minutes
Density0.95 ± 0.02 g/cm³
pH Value9.5 ± 0.3
Recommended Concentration (Immersion)10-30 g/l

Frequently asked questions

What is the minimum temperature for use?

The product is used for spray and immersion treatment at temperatures above 10°C.

What is the minimum temperature required for using P3-emulpon 6771?

The product is intended for spray and immersion processes at temperatures above 10°C.

What is the recommended concentration range for immersion applications?

The recommended concentration for immersion is between 10 and 30 g/l.

How much product is needed per degree of German hardness to avoid foam?

You need 10 g/l of the product for every 1° German hardness.