Northern Pump NPC-1-D100481 Gear Pump Operation Manual

This document is an operation manual for the Northern® NPC Pump Model NPC-1-D100481, providing information on installation, startup, operating limits, lubrication, and preventative maintenance.


Northern Pump NPC-1-D100481 Gear Pump Operation Manual - cover page
Brand
Northern Pump
Document type
User Manual
Language
English
Pages
15
File format
PDF
File size
178 KB
Published
14 September, 2022
Updated
27 September, 2023
MD5 checksum
0FD683593BFEB1464B41CAB2AEA2E037

About this manual

The document is an operation manual for the Northern Pump NPC-1-D100481 model. It covers safety precautions, installation procedures including shaft coupling alignment, and startup requirements such as priming methods. The manual details operating limits regarding pressure, speed, viscosity, and temperature to ensure pump longevity.

What's inside

  • Cautionary Statements
  • Installation
  • Startup
  • Operating Limits
  • Performance Considerations
  • Lubrication and Preventative Maintenance
  • Trouble Shooting Guide
  • Removal from Installation
  • Parts List

Specifications

Maximum discharge pressure100 psig (690 kPag)
Suction vacuum limit15 inches of mercury
Speed range5 – 300 rpm
Viscosity range50 – 20,000 cP
Temperature range-20 °F to +250 °F (-29 °C to +121 °C)

Frequently asked questions

How should the pump be primed if the suction vessel is below the pump?

Put a small amount of compatible liquid into the pump, keep discharge pressure low, eliminate vacuum leaks, and operate at moderate speed (150–200 rpm).

What is the recommended rotational speed for priming?

The pump should be operated at moderate speed, specifically between 150 and 200 rpm.

What causes a pump to require too much torque?

It may be caused by abnormally high liquid viscosity or binding of the pump shaft.

Download PDF (178 KB)