This document is an operation manual for the Northern® NPC Pump Model NPC-1-D100481, providing information on installation, startup, operating limits, lubrication, and preventative maintenance.
The document is an operation manual for the Northern Pump NPC-1-D100481 model. It covers safety precautions, installation procedures including shaft coupling alignment, and startup requirements such as priming methods. The manual details operating limits regarding pressure, speed, viscosity, and temperature to ensure pump longevity.
| Maximum discharge pressure | 100 psig (690 kPag) |
|---|---|
| Suction vacuum limit | 15 inches of mercury |
| Speed range | 5 – 300 rpm |
| Viscosity range | 50 – 20,000 cP |
| Temperature range | -20 °F to +250 °F (-29 °C to +121 °C) |
Put a small amount of compatible liquid into the pump, keep discharge pressure low, eliminate vacuum leaks, and operate at moderate speed (150–200 rpm).
The pump should be operated at moderate speed, specifically between 150 and 200 rpm.
It may be caused by abnormally high liquid viscosity or binding of the pump shaft.