Edwards Model 20 / Model 80 Pump Maintenance Manual

This document is a maintenance manual for Edwards Model 20 / Model 80 pumps. It covers safety precautions, maintenance materials, lubrication, troubleshooting, removal, disassembly, cleaning, inspection, repair and replacement, and installation.


Edwards Model 20 / Model 80 Pump Maintenance Manual - cover page
Brand
Edwards
Category
Industrial Robot
Document type
Service Manual
Language
English
Pages
39
File format
PDF
File size
1.9 MB
Published
26 August, 2022
Updated
28 September, 2023
MD5 checksum
C37B1FF73756D6D93B440894A8826DE5

About this manual

This manual provides maintenance procedures for Edwards Model 20 and Model 80 pumps, which are standard-duty high-speed gear-driven positive-displacement rotary pumps. It covers safety precautions, consumable materials, lubrication schedules, and troubleshooting guides for common issues such as excessive noise, vibration, and reduced flow. The document emphasizes the importance of verifying the model number (20-420) and serial number before performing any maintenance to prevent pump failure or injury.

The guide details step-by-step procedures for removal, disassembly, cleaning, inspection, repair, and reassembly. It also includes installation instructions for unpacking, mounting, leveling, and piping. A comprehensive parts list is provided for Model 80 pumps, listing specific part numbers and quantities for various components like timing gears, bearings, and seals.

What's inside

  • Safety General Precautions
  • Consumable Materials
  • Lubrication
  • Troubleshooting
  • Removal
  • Disassembly
  • Cleaning
  • Inspection
  • Repair and Replacement
  • Assembly

Specifications

Self-primingYes
Timing Gear Noise LimitAbove 900 rpm
Recommended Model Number20-420

Frequently asked questions

What are the recommended lubrication intervals for the pump?

Bearings should be lubricated every 6,000 hours with 0.25 ounce of grease, and timing gears every 6,000 hours with 1.00 ounce of grease.

At what speed do the pump's timing gears become very noisy?

The timing gears can be very noisy when the pump is operated above 900 rpm.

How much grease is required for the bearings and timing gears after 6,000 hours of operation?

The bearings require 0.25 ounce of grease and the timing gears require 1.00 ounce of grease.

What is the maximum vacuum reading allowed on the suction piping to avoid cavitation?

The vacuum gauge should read less than 10-in. Hg in most cases.

Download PDF (1.9 MB)

More Edwards Manuals


View all Edwards manuals →