This document provides operation and installation instructions for the Crusader Water Systems UV Disinfection system. The system is capable of effectively inactivating microorganisms in the water supply, ensuring safe drinking water. The system features simple maintenance, continuous disinfection, and safe water supply.
This manual provides operation and installation instructions for Crusader Water Systems UV disinfection systems, including models CWS 5-031 through CWS 6-201. It outlines safety considerations, required tools, and water quality parameters necessary for effective disinfection.
The document details the assembly process, including unpacking components, selecting a suitable location within 5 feet of a GFCI, and installing the reactor horizontally or vertically. It also covers the installation steps for copper plumbing, quartz sleeve assembly, and connecting the UV sensor for Crusader6.0 models.
| Recommended pre-filtration | at least 5 microns |
|---|---|
| Controller location distance | within 5 feet of a GFCI |
| Hardness limit | <7 gpg (120 mg/L) |
| Iron limit | <0.3 ppm (0.3 mg/L) |
| Manganese limit | <0.05 ppm (0.05 mg/L) |
| Turbidity limit | < 1 NTU |
| Tannins limit | <0.1 ppm (0.1 mg/L) |
| UVT requirement | >85% |
You will need a pipe cutter or hacksaw, soldering tools (torch, flux, emery cloth, and solder), and a wrench for tightening fittings.
Yes, the reactor can be installed either horizontally or vertically, though vertical installation with the inlet at the bottom is the preferred method.
For Point of Entry (POE), it should be the last piece of treatment before water branches to hot and cold lines. For Point of Use (POU), it should be the final step before the faucet.
The water hardness should be less than 7 gpg (120 mg/L) to ensure efficient UV penetration without excessive cleaning of the quartz sleeve.