This document is a user manual for the Panasonic HG-S□ MCK-HGS1010 digital displacement sensor, including applicable specifications/regulations, installation methods, names of various parts, and specifications.
This document is the user manual for the Panasonic HG-S□ series digital displacement sensors (detection heads). It covers safety precautions, unpacking, installation procedures for the sensor head and connecting cable, and removal methods. The manual also includes specifications for various models within the series. This manual is written in Chinese.
| Detection Method | Optical Absolute Linear Encoder |
|---|---|
| Stroke Range | 105mm or more |
| Operating Temperature | -10°C to +55°C |
| Storage Temperature | -20°C to +60°C |
| Protection Class | IP67 |
| Mechanical Life | 100 million times or more |
| Operating Load | 1.65N or less |
No, this product should not be used for human protection devices. For such applications, use products complying with relevant laws and specifications such as OSHA, ANSI, and IEC.
The tightening torque must be controlled to 12.5 N·mm or less during installation.
No, the product should not be used outdoors.
If the rubber boot is deformed, it may cause load on the measurement axis during operation, leading to damage.