STMicroelectronics TN22 Fluorescent Tube Lamp Starter SCR Datasheet

The document describes the features and characteristics of the TN22 fluorescent tube lamp starter, including high clamping voltage structure, low gate triggering current, and high holding current. This product provides high energy striking characteristics with low triggering power, improving the reliability and lifespan of fluorescent tube lamps.


STMicroelectronics TN22 Fluorescent Tube Lamp Starter SCR Datasheet - cover page
Brand
STMicroelectronics
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
13
File format
PDF
File size
321 KB
Published
10 August, 2012
Updated
29 September, 2023
MD5 checksum
6D8D1EF0123A8E8DAD0C914F9A07CC11

About this manual

The TN22 is a Fluorescent tube lamp starter SCR specifically developed for use in tube lamp electronic starter circuits. It features a high clamping voltage structure (1200 to 1500 V) and low gate triggering current for direct drive from the line, ensuring high reliability and extended life for fluorescent lamps.

The document provides absolute ratings, electrical characteristics, and static electrical characteristics for the device. It also includes application information describing the electronic starter circuit schematic and the three operating steps: preheating, ignition, and lighting.

What's inside

  • Features
  • Absolute ratings
  • Electrical characteristics
  • Thermal resistance
  • Application information
  • Ordering information

Frequently asked questions

What is the typical preheating time duration?

The preheating time is typically in the range of 2 to 3 seconds depending on the tube characteristics.

What voltage level is necessary for correct ignition?

A 1200 V to 1500 V level is necessary to ensure a correct ignition of the fluorescent tubes.