Sentrol R1275 Series Magnetic Contacts Installation Instructions

SENTROL is a 100% tested solution for applications such as Gap distance, Closed loop, and Open loop SPDT. It is UL listed and available in various colors and sizes.


Sentrol R1275 Series Magnetic Contacts Installation Instructions - cover page
Brand
MARS
Category
Other Electronics
Document type
Installation Guide
Language
English
Pages
2
File format
PDF
File size
78 KB
Published
07 August, 2012
Updated
29 September, 2023
MD5 checksum
7B78405D621EB403E1044BCFDFE279F3

About this manual

This document provides installation instructions for the Sentrol R1275 Series Mini-Max magnetic contacts. It covers the assembly of the switch and magnet components, including drilling holes and applying RTV mounting compound. The guide details two mounting methods: surface mounting the magnet to a window frame and recessed mounting the magnet into a hole.

What's inside

  • Installation Instructions
  • Switch Assembly
  • Magnet Mounting
  • Recess Mount Magnet
  • UL Specifications
  • Gap Specifications

Specifications

Voltage100 VAC/DC MAX
Current0.5 AMAX
Power7.5 W MAX
Standard Gap0.125"
Wide Gap1.00"

Frequently asked questions

What is the standard gap distance for the R1275 switch?

The standard gap distance is 0.125 inches.

What is the maximum voltage for the R1275 Series?

The maximum voltage is 100 VAC/DC.

How should the magnet be mounted for a recessed installation?

Drill a hole approximately 1/8" deep and coat the magnet with RTV or silicon adhesive before mounting.

Download PDF (78 KB)