This manual provides instructions for the Thunder Power TP610C RC charger, a digital power system designed for safely charging LiPo, NiMH, Nicd, PB, and A123 batteries. The device features a backlit LCD display, programmable memory profiles, and specific algorithms for different battery chemistries, including recovery modes for over-discharged packs.

The document details the physical layout of the unit, including the LCD screen, upgrade connector, and BL-2 balance tap connector. It outlines system features such as individual cell overcharge protection, adjustable charge/discharge cycles, and input/output polarity protection. Safety cautions and step-by-step procedures for connecting power, setting battery chemistry, and initiating charge or discharge cycles are included. This manual is written in Chinese.

What's inside

  • System Features
  • Specifications
  • Cautions
  • Connection to Power Supply
  • System Option Settings
  • LCD Display Abbreviations
  • LiPo/A123 Charge Sequences
  • Battery Recovery Mode
  • NiCd/NiMH Charge
  • Safety Functions

Specifications

Input Power11-16V DC/10Amp at maximum charge rate
Supported Battery ChemistriesLipo/NiMH/Nicd/PB/A123
Charge Current0.25A---10A
Charge Control TypeLipo/A123: CC/CV; Nicd/NiMH: constant current –V delta peak
Charge/Discharge Cycles9 cycles
Display TypeBacklit 2 x 16 dot LCD
Charge Maximum Output80 Watt
Dimensions118 x 85 x 28 (mm)
Weight265g/9.4OZ

Frequently asked questions

What battery chemistries does the TP610C support?

The charger supports Lipo, NiMH, Nicd, PB, and A123 battery chemistries.

What is the maximum charge current?

The maximum charge current is 10A.

How do I check the balancer data?

Press the [SEL] key for 2 seconds to display the balancer data on the LCD.

What happens if a cell reaches 4.28V during charging?

The charging process will be interrupted with an error message.