This document is an installation, operational, and service manual for a swimming pool pump and filter system. The manual includes instructions on how to install the system, initial start-up, component care, cleaning frequency, filter backwash procedure, chemical cleaning, replacement of valve top and diverter assembly, winterizing the components, and troubleshooting.
This document serves as the Installation, Operational, and Service Manual for a Pentair swimming pool pump and filter system. It details how the system works, including the flow of water through the centrifugal pump and sand filter. The guide emphasizes safety warnings regarding high pressure and air in the system to prevent injury or property damage.
| Motor Horsepower Options | 3/4 HP, 1 HP, 1 1/2 HP |
|---|---|
| Filter Sand Type | No. 20 standard silica sand |
| Sand Uniformity Coefficient | 1.75 or less |
Proper pool sanitation requires a free chlorine level of 1 to 2 PPM.
The recommended pH range is between 7.2 and 7.6.
The system must turnover the total volume of water at least twice in a twenty-four hour period.