Fairchild FAN6747WL Highly Integrated Green-Mode PWM Controller Datasheet

The FAN6747WL is a highly integrated green-mode PWM controller with features such as high-voltage startup, AC-line brownout protection, constant output power limit, and built-in 8ms soft-start function.


Fairchild FAN6747WL Highly Integrated Green-Mode PWM Controller Datasheet - cover page
Brand
Fairchild
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
15
File format
PDF
File size
915 KB
Published
01 August, 2012
Updated
28 September, 2023
MD5 checksum
0EF6F1D17A6D47FDE06D839F4F32832F

About this manual

The FAN6747WL is a highly integrated PWM controller designed specifically for SMPS with peak-current output, such as printers, scanners, and motor drivers. It incorporates cycle-by-cycle current limiting and two-level over-current protection (OCP) to handle peak loads effectively.

To minimize standby power consumption and meet international power conservation requirements, the device features a proprietary Green-Mode function that decreases switching frequency under light load conditions. The controller also includes built-in soft-start, short-circuit protection, and over-voltage protection with internal latching circuits.

What's inside

  • Features
  • Applications
  • Description
  • Ordering Information
  • Application Diagram
  • Pin Configuration
  • Absolute Maximum Ratings
  • Electrical Characteristics

Specifications

Operating Junction Temperature Range-40 to +125 °C
Storage Temperature Range-55 to +150 °C

Frequently asked questions

What is the operating ambient temperature range?

The recommended operating ambient temperature range is from -40°C to +105°C.

What type of protection does the FAN6747WL offer for over-temperature?

It offers Over-Temperature Protection (OTP) using an external Negative-Temperature-Coefficient (NTC) thermistor connected to the RT pin.

Does this controller support Green-Mode operation?

Yes, it includes a proprietary Green-Mode function that decreases switching frequency to reduce standby power consumption.