JOST JF1 2/...E500-JF132/...E500 technology data

This document is an operating manual for the frequency converter JF1,2/. to JF132/. (installation kit JF../.E500). The document emphasizes electrical safety issues and warns users to be careful and cautious during operation and connection to avoid electric shock and other injuries.


JOST JF1 2/...E500-JF132/...E500 technology data - cover page
Brand
JOST
Document type
User Manual
Language
German
Pages
96
File format
PDF
File size
873 KB
Published
10 July, 2012
Updated
29 September, 2023
MD5 checksum
6E6BD0DF2AA8ED2F34D51A95B76D635A

About this manual

The JOST JF series frequency converters are described in this operating manual. It provides detailed safety instructions, EMV compliance notes, and general information about the device’s purpose and construction.

The document includes technical data, mechanical installation guidelines, wiring diagrams, control‑panel functions, commissioning steps, fault‑search procedures, and optional features. It is intended for qualified electrical personnel who install, commission, and maintain the converters. This manual is written in German.

What's inside

  • Electrical Safety
  • EMV Law and CE Marking
  • General Information
  • Incoming Inspection
  • Technical Data
  • Mechanical Installation
  • Wiring and Cabling
  • Control Panel
  • Commissioning
  • Fault Search

Specifications

Nominal input voltage380 V – 440 V, 50/60 Hz
Dimensions (JF 1,2/...E500)128 mm × 292 mm × 190 mm
Output frequency range0 – 320 Hz
Network frequency range45 Hz – 66 Hz

Frequently asked questions

Who is allowed to perform the electrical installation?

Only qualified and trained electrical personnel may carry out the installation.

How is the converter grounded?

It must be connected to earth via the PE terminal using an earth lead.

What CE directives does the converter comply with?

The CE mark refers to the Low‑Voltage Directive 73/23/EWG (93/68) and the Electromagnetic Compatibility law (EWG §5.2 9/92).