Gelbau 452.4x Safety Switch Device Operating Manual

The 452.4x safety switch device is designed specifically for monitoring GELBAU Contact-Duo safety switch panels, which use an 8.2 kiloohm resistor as an electrical terminal. The 452.4x series is a dual channel design that includes redundancy monitoring. The emergency stop outputs (13-14, 23-24) consist of 2 forced-action relays and include a reset function. A notification or auxiliary contact is available through an additional changeover contact (31, 32, 34). The safety system meets the EN ISO 13849-1:2005 standard as well as the European switch panel standard EN1760-2 with regard to the output switching device.


Gelbau 452.4x Safety Switch Device Operating Manual - cover page
Brand
Gelbau
Document type
User Manual
Language
German
Pages
4
File format
PDF
File size
125 KB
Published
10 July, 2012
Updated
30 September, 2023
MD5 checksum
892E63310CC2B2C06898099393EA8C81

About this manual

This manual describes the Gelbau 452.4x safety switch device, which monitors GELBAU Contact‑Duo safety bus bars using an 8.2 kΩ resistor. It covers general information, wiring, function, installation, commissioning, and fault diagnosis.

Technical data such as housing material, dimensions, electrical ratings, and compliance with EN ISO 13849‑1 and EN 62061 are listed, along with safety relay specifications and environmental limits. This manual is written in German.

What's inside

  • Allgemeines
  • Aufbau, Anschluss
  • Funktion
  • Funktionstabelle (Statusanzeige)
  • Montage, Inbetriebnahme
  • Fehlersuche und Maßnahmen
  • Technische Daten
  • EG-Konformitätserklärung

Specifications

Housing materialPolyamid PA 6.6
Protection classIP20
Dimensions (B × H × T)22.5 × 100 × 110 mm
Weight175‑250 g
Maximum load per safety relay output4 A
Maximum switching voltage250 V AC
Sensor idle current≈ 0.6 mA
Mechanical contact life3 × 10⁷ cycles

Frequently asked questions

How do you start the 452.4x device?

Press the reset contact (Y1, Y2) briefly to start the device.

What is the maximum current rating for the safety relay contacts?

Each safety relay contact (13‑14, 23‑24) can be loaded up to 4 A.

Download PDF (125 KB)