These instructions describe the installation and operation of the TK5 control unit.
The JOST S‑TK5001 control unit is used to regulate magnetic oscillation equipment. The manual provides detailed electrical safety guidelines, EMVG compliance notes, and the intended use of the unit, including amplitude adjustment via potentiometer or external signal.
Installation instructions cover design, cooling, mounting, cabling, and connections, followed by commissioning steps, adjustment procedures, maintenance, and a technical data annex with specifications and wiring diagrams.
| Nominal mains voltage | 115 V / 230 V AC (1Ph+N) |
|---|---|
| Mains voltage ranges | 100‑120 V AC and 200‑240 V AC |
| Maximum output current | 5 A |
| Power loss (max) | 6 W |
| Internal voltages | ±12 V stabilised, short‑circuit proof |
| Target value input | 0‑4 – 20 mA (load 250 Ω) or 0‑10 V |
| Operating temperature | 0 °C to +45 °C |
| Storage temperature | -10 °C to +85 °C |
| Dimensions (W×D×H) | 110 mm × 112 mm × 197 mm |
| Weight | 700 g |
| Approvals | EN 50081‑1, EN 50082‑2 |
A cable length of up to 150 m is foreseen; longer distances require an increased cable cross‑section.
The maximum output current is 5 A.