JOST S‑TK5001 Control Unit Operating Instructions

These instructions describe the installation and operation of the TK5 control unit.


JOST S‑TK5001 Control Unit Operating Instructions - cover page
Brand
JOST
Document type
User Manual
Language
English
Pages
20
File format
PDF
File size
243 KB
Published
10 July, 2012
Updated
30 September, 2023
MD5 checksum
92C1C766B0B73FCAE7B8B501B5A8E94C

About this manual

The JOST S‑TK5001 control unit is used to regulate magnetic oscillation equipment. The manual provides detailed electrical safety guidelines, EMVG compliance notes, and the intended use of the unit, including amplitude adjustment via potentiometer or external signal.

Installation instructions cover design, cooling, mounting, cabling, and connections, followed by commissioning steps, adjustment procedures, maintenance, and a technical data annex with specifications and wiring diagrams.

What's inside

  • Electrical Safety
  • EMVG Act Notes
  • Intended Use
  • Method of Working
  • Installation Design
  • Cabling and Connections
  • Particularities
  • Commissioning
  • Adjustment / Reconfiguration
  • Technical Data

Specifications

Nominal mains voltage115 V / 230 V AC (1Ph+N)
Mains voltage ranges100‑120 V AC and 200‑240 V AC
Maximum output current5 A
Power loss (max)6 W
Internal voltages±12 V stabilised, short‑circuit proof
Target value input0‑4 – 20 mA (load 250 Ω) or 0‑10 V
Operating temperature0 °C to +45 °C
Storage temperature-10 °C to +85 °C
Dimensions (W×D×H)110 mm × 112 mm × 197 mm
Weight700 g
ApprovalsEN 50081‑1, EN 50082‑2

Frequently asked questions

How long can the power cable be between the control unit and the drive?

A cable length of up to 150 m is foreseen; longer distances require an increased cable cross‑section.

What is the maximum output current of the TK5 control unit?

The maximum output current is 5 A.