Hanna Instruments HI 93740 Nickel Low Range ISM Instruction Manual

This document is the instruction manual for HI 93740 Nickel Low Range ISM instrument, which describes the design, construction, and appearance features of the instrument. It is warranted for two years and covers free repair or replacement. Damages due to accidents, misuse, tampering, or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. If the repair is not covered by the warranty, you will be notified of the charges. To validate the warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase.


Hanna Instruments HI 93740 Nickel Low Range ISM Instruction Manual - cover page
Brand
Hanna Instruments
Category
Other Electronics
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
308 KB
Published
10 July, 2012
Updated
29 September, 2023
MD5 checksum
8253B59216996CE60E464A98DD7679F4

About this manual

The HI 93740 is a portable instrument designed to measure nickel concentrations in the range of 0.000 to 1.000 mg/L (ppm). It utilizes an exclusive positive-locking system for cuvet placement and employs the PAN method, where the reaction between nickel and reagents creates an orange tint detected by a silicon photocell.

The document details the measurement procedure involving specific reagents (phthalate-phosphate, PAN indicator, and EDTA) added to samples in graduated beakers. It also covers operational tips for accurate readings, interference factors from various ions, battery replacement instructions, and troubleshooting display codes.

What's inside

  • Warranty Information
  • Preliminary Examination
  • Specifications
  • Required Reagents
  • Display Code Guide
  • Measurement Procedure
  • Interferences
  • Tips for Accurate Measurement

Specifications

Range0.000 to 1.000 mg/L
Resolution0.001 mg/L
Accuracy+ 0.01 mg/L + 7% of reading
Light SourceLED @ 555 nm
Battery Life40 hours

Frequently asked questions

What is the measurement range for nickel?

The meter measures nickel content in the 0.000 to 1.000 mg/L (ppm) range.

How long does it take for the reaction to develop?

After adding the PAN solution, you must wait for 15 minutes before proceeding.

What happens if the battery is low?

The display will show a 'V' indicating low voltage; once dead, the meter locks up until replaced.

Download PDF (308 KB)

More Hanna Instruments Manuals


View all Hanna Instruments manuals →