The document describes the features and characteristics of a product, but further analysis is needed for specific details.
This document provides safety guidelines and operational procedures for the Actron CP7672 Digital Multiprobador. It covers essential safety precautions such as using fire extinguishers, wearing protective eyewear, avoiding loose clothing, ensuring proper ventilation to prevent carbon monoxide poisoning, and handling high voltage components like ignition coils.
The manual details the specifications of the device, including its LCD display size, automatic polarity detection, and operating temperature range. It outlines specific measurement functions for AC/DC voltage, current (mA and 10A), resistance, diode testing, and transistor hFE testing, along with step-by-step procedures for connecting test leads and interpreting readings. This manual is written in Spanish.
| Display Type | 1.27cm (0.5 pulgadas) LCD, 3 digits |
|---|---|
| Operating Temperature | -0°C a 35°C / 32°F a 95°F |
| Relative Humidity | 0-80% at 35°C / 0-70% at 50°C |
| Measurement Speed | 2.5 measurements per second |
| Internal Battery | 9V alkaline or carbon-zinc (NEDA1604) |
| AC Voltage Range | 200V, 750V, 1000V |
| DC Current Range | 200uA, 2mA, 20mA, 200mA, 10A |
| Resistance Range | 200Ω, 2KΩ, 20KΩ, 200KΩ, 2MΩ |
A fire extinguisher of at least 2.27kg CO2 or specified chemical product unit should be available.
No, the 10 ampere range on this multimeter is not protected by a fuse.