This is a user manual, mainly introducing the use methods, maintenance methods and precautions of the air conditioner product
This manual covers important safety notices for operating the AlpicAir AWI/AWO‑Delta air conditioners, including voltage stability, proper power cord use, and ventilation requirements. It also explains the working principles for cooling and heating modes, anti‑freezing and auto‑defrost functions, and how to adjust airflow direction.
Additional sections describe the parts of indoor and outdoor units, step‑by‑step cleaning and care procedures, and a detailed troubleshooting guide that helps identify common issues such as bad smells, water leakage, and abnormal noises, with recommended actions and when to contact an authorized service center.
Clean the air filter, as the smell is usually accumulated from the environment, not the unit itself.
During auto defrosting the controller stops the fan motors of both indoor and outdoor units for about 8‑10 minutes, then resumes operation automatically.
Turn off the main power and unplug the power plug to avoid electric shock.
It is recommended to clean the air filters at least once every three months, or more frequently if dust accumulation is high.