This is an operating manual for the EA-PSP 5612, which introduces its basic functions, usage methods, interfaces, etc.
The EA‑PSP 5612 provides both an IEEE‑488.2 (GPIB) and an RS‑232 interface for controlling power supplies. It supports up to 32 IEEE addresses via a 6‑position DIP switch and offers a default RS‑232 baud rate of 9600 Baud. The manual describes hardware connections, configuration settings, and SCPI command programming.
Key sections cover technical specifications, interface wiring, address and baud‑rate settings, serial‑connection properties, and detailed SCPI command usage, including voltage/current programming, status queries, and safety‑feature controls. This manual is written in German.
| Dimensions | 160 mm × 100 mm |
|---|---|
| Interface standards | IEEE488.2, RS‑232‑C |
| IEEE connector | 24‑pin Amphenol socket (IEEE‑488) |
| Digital supply voltage | +5 V, ca. 350 mA, ±5 % |
| Analog supply voltage | +15 V, ca. 20 mA |
| Analog output range (U‑set) | 0 V … 10 V (typical) |
| Resolution | 12 bit (≈2.44 µV per LSB) |
| Temperature coefficient | max 10 ppm/°C |
| Response time | ≈5 ms after LF character |
Up to 32 addresses can be set using the 6‑position DIP switch.
The interface is preset to 9600 Baud by default.
The analog output can be programmed from 0 V to 10 V (typical).
A 24‑pin Amphenol socket is used for the IEEE‑488 connection.