Nokia PremiCell 09i/18i User Manual

This document provides Nokia mobile phone user manual, including safety information, installation instructions, connection instructions etc.


Nokia PremiCell 09i/18i User Manual - cover page
Brand
Nokia
Category
Cell Phones
Document type
User Manual
Language
English
Pages
22
File format
PDF
File size
376 KB
Published
02 May, 2012
Updated
30 September, 2023
MD5 checksum
F3E54F00A0FDA45DF86F86A15D9F0E21

About this manual

The Nokia PremiCell 09i/18i is a GSM‑based telecommunication terminal that enables phone calls, fax, and data services where landline connections are unavailable. It connects to a standard telephone and can be powered from an AC adapter or optional backup battery.

This guide covers important safety notices, the contents of the sales package, installation and positioning, daily operation such as making calls, voice mail and SMS handling, accessory information, troubleshooting, care and maintenance, and detailed technical specifications.

What's inside

  • Important Safety Information
  • Introduction
  • Sales Package Contents
  • Putting Terminal Into Use
  • Daily Use
  • Making and Receiving Calls
  • Voice Mail and SMS
  • Care and Maintenance
  • Technical Specifications

Specifications

Dimensions121x213x28 mm
Weight800 g
Call Current (PremiCell 18i)1200 mA
Call Current (PremiCell 09i)1500 mA
Idle Current300 mA
Stand‑by Time (with backup battery)10 h
Talk Time (PremiCell 18i)2.5 h
Battery Voltage6.8 V nominal
Charger TypeSwitched mode power supply
Input Voltage187‑264 V
Output Voltage6.8 V ±0.1 V
Output Current1600 mA max
DC Connector5.5 mm DC plug
Cable Length1500 mm
Operating Conditions-10 °C … +55 °C
Storage Conditions-40 °C … 470 °C

Frequently asked questions

What is the standby time when using the optional backup battery?

The standby time is 10 hours.

Download PDF (376 KB)