Hobart C44BR Dishwasher Installation Manual

The C44BR dishwasher is a fully automatic rack machine with stainless steel water tank, washing chamber, dish rack and guide rail, as well as stainless steel support and adjustable stainless steel foot pads. The machine is equipped with a 36KW, 18KW spray booster heater, which can be heated by steam or electricity. It features automatic timer switch, motor switch, cleaning temperature meter, and spray temperature meter.


Hobart C44BR Dishwasher Installation Manual - cover page
Brand
C44BR洗碗机
Category
Cleaning machines
Document type
User Manual
Language
Chinese
Pages
22
File format
PDF
File size
358 KB
Published
10 April, 2012
Updated
29 September, 2023
MD5 checksum
76E188C0742F74B9B6BD6B70DB8F13A5

About this manual

The Hobart C44BR is a fully‑automatic rack‑type dishwasher featuring a stainless‑steel water tank, wash chamber, rack, guide rails and stainless‑steel support frame. It offers both steam and electric heating options with built‑in temperature gauges.

This manual includes basic parameters, standard and optional equipment, detailed installation procedures (unpacking, assembly, water and drain pipe connections, steam and electrical wiring), operating programs, cleaning, maintenance, ventilation, lubrication, and troubleshooting information. This manual is written in Chinese.

What's inside

  • Overview
  • Basic Parameters
  • Standard Equipment
  • Optional Equipment
  • Installation
  • Water Pipe Connection
  • Electrical Connection
  • Operation
  • Maintenance
  • Troubleshooting

Specifications

Dimensions (L×W×H)1725×763×1685 mm
Maximum Wash Load203 baskets per hour (4000 plates)
Maximum Wash Height450 mm
Wash Heating Power7.5 kW
Spray Heating Power36/18 kW (selectable)
Total Power Consumption46/28 kW
Maximum Water Consumption per Hour420 L
Water Consumption per Basket2.07 L
Spray Water per Basket5.47 L

Frequently asked questions

What must be checked before making the electrical connection?

Refer to the machine data plate for the correct power supply, ensure compliance with ANSI/NFPA 70 and local codes, cut power and hang a warning sign before any work.

Download PDF (358 KB)