This manual explains safety precautions, proper installation, and correct operation of the AD-1294N dehumidifier. It covers power requirements, placement, ventilation, and how to use the control panel and settings.
Maintenance procedures, water‑tank handling, drain‑pipe installation, moving the unit, cleaning, troubleshooting, and full product specifications are detailed to help users keep the dehumidifier running safely and efficiently. This manual is written in Chinese.
| Model | AD-1294N |
|---|---|
| Power Supply | 110Vac, 60Hz |
| Dehumidifying Capacity | 6 L/d (27 °C, 60 %RH) |
| Power Consumption | 210 W |
| Rated Current | 2.7 A |
| Operating Temperature | 5 °C ~ 35 °C |
| Weight | 13.5 kg |
| Dimensions (H × W × D) | 50.7 × 32.3 × 28.5 cm |
Turn off the unit, pull the water‑tank out, hold it steady and tilt to pour out the water, then rinse with clean water before reinstalling.
The water‑level indicator lights up and the dehumidifier stops operating; empty the tank to resume use.