This document is an operating manual for the 3D-Master Vita System, providing information on the technical specifications, program possibilities, safety functions, installation and start-up, and important notes.
This manual covers the safe and efficient operation of the VITA VACUMAT 40T furnace. It includes forewords, technical information, program possibilities, safety functions, installation, start‑up, and detailed instructions for cleaning, maintenance, and troubleshooting.
The document also describes the device’s hardware features, such as the colour touchscreen display, internal memory for firing programs, and safety monitoring functions. It provides guidance on program creation, lift position settings, vacuum calibration, and software updates via a memory stick.
| Temperature accuracy | ± 2 °C |
|---|---|
| Program memory capacity | ≈ 200 firing programs |
| Display type | Colour touchscreen |
| Housing material | Paint‑finished sheet steel and stainless steel |
The internal memory can hold approximately 200 firing programs.
Yes, the standby temperature can be set in the program menu (see section 13).