This document describes the recycling methods for ALTIVAR 12 0.75 kW / 100V / 1 PH, 1.5–2.2 kW / 200V / 1PH products.
This document provides end‑of‑life (EoL) instructions for the Schneider ALTIVAR12 power unit. It outlines recommended operations such as reuse, depollution, dismantling and shredding to recover components, materials, or energy while complying with WEEE regulations.
Key safety information includes removing all power and waiting 15 minutes before servicing, due to the presence of electrolytic capacitors that can cause electric shock. The guide lists components that require special handling, such as printed circuit board assemblies and electrolytic capacitors, and identifies parts suitable for reuse or dismantling.
| Power rating (100 V) | 0.75 kW / 1 PH |
|---|---|
| Power rating (200 V) | 1.5‑2.2 kW / 1 PH |
| Dimensions (W × H × D) | 105 mm × 142 mm × 156 mm |
All power must be removed and a 15‑minute waiting period observed before servicing.
Printed Circuit Board Assembly (PCBA) and electrolytic capacitors are listed for depollution.