Bucher Hydraulics Typ A DF/A DH Datasheet

This document is the user manual of the pressure relief valve produced by Bucher Hydraulics GmbH. It details the function, features, specifications, installation methods, etc. of the product.


Bucher Hydraulics Typ A DF/A DH Datasheet - cover page
Brand
BUCHER-Typ
Category
Other
Document type
Datasheet
Language
German
Pages
4
File format
PDF
File size
192 KB
Published
19 March, 2012
Updated
30 September, 2023
MD5 checksum
B8E8F8875EC56808899166C84688BFF3

About this manual

This datasheet provides the technical specifications for the Bucher Hydraulics pressure‑limiting valve of type A DF/A DH. It includes the pressure adjustment ranges, flow capacities, temperature limits, viscosity range and the dimensions of the valve body and its thread connections.

The document also lists the available thread sizes (SAE 1/2", 3/4" and 1"), optional integrated back‑pressure valve options, and ordering information such as part numbers and required accessories. This manual is written in German.

What's inside

  • Applications
  • Characteristic Curve
  • Technical Data
  • Dimensions
  • Thread Connections
  • Ordering Information

Specifications

Adjustment range10–350 bar (three pressure stages)
Opening pressure (RV)0–3 bar
Medium temperature range-20 °C to +80 °C
Viscosity range10–300 mm²/s
Nominal flow (SAE 1/2")40 L/min
Nominal flow (SAE 3/4")80 L/min
Nominal flow (SAE 1")120 L/min

Frequently asked questions

What is the pressure adjustment range of the valve?

The valve can be set from 10 to 350 bar in three pressure stages.

Which thread sizes are available for the valve connections?

Thread connections are offered in SAE 1/2", SAE 3/4" and SAE 1" sizes.

Can the valve be equipped with an integrated back‑pressure valve?

Yes, an integrated back‑pressure valve (R) is possible when the valve is built with a thread connection.

What are the operating temperature limits for the hydraulic fluid?

The fluid temperature may range from –20 °C to +80 °C.

Download PDF (192 KB)