This user manual is the user manual of the environmental protection antibacterial refrigerator SR-586QV. It mainly introduces the use method, precautions, safety precautions, installation precautions, emergency treatment methods, platinum deodorization principle introduction and other contents of the refrigerator.
This manual explains how to safely install the SR-586QV refrigerator, including placement on a flat surface, required ventilation clearances, and grounding instructions. It also covers proper use of the door, temperature settings, and the built‑in deodorizing system.
Maintenance procedures such as regular cleaning of the water drainage system, periodic deodorizer replacement, and troubleshooting steps for abnormal noises or burning smells are detailed, along with a full list of technical specifications for the unit. This manual is written in Chinese.
| Rated Voltage (V) | 110 |
|---|---|
| Rated Frequency (Hz) | 60 |
| Motor Rated Power (W) | 165 |
| Heater Rated Power (W) | 140 |
| Total Internal Volume (L) | 580 |
| Compartment Volumes (L) – Freezer / Chiller / Vegetable | 153 / 302 / 125 |
| Monthly Power Consumption (kWh) | 72 |
| Energy Efficiency (L/kWh·month) | 9.71 |
| Refrigerant Type | R‑134a |
| Refrigerant Charge (g) | 145 |
| Product Weight (kg) | 95 |
Place the unit on a flat surface, keep at least 10 cm clearance behind and above the refrigerator, and ensure the surrounding area is well ventilated.
Stop the refrigerator immediately and disconnect the power supply.
Clean the drainage system about once a month to prevent buildup and odors.
The refrigerator is rated for 110 V.