SAS816 floor heating temperature controller is a passive signal control output product for floor heating control system, supporting Fahrenheit and Celsius temperature display selection, cooling mode is effective, used to select the compressor protection function, and supporting system power on and off function, as well as energy saving or comfortable running mode selection.
The SAS816WHL-0 controller is designed for floor heating systems and can work with both active and passive signal outputs. It offers temperature display selection, control mode switching, on/off functions, running mode selection, and compressor protection. The device is non‑programmable and includes temperature accuracy of ±1 ℃/±1 ℉.
The manual explains how to set DIP switches for temperature units, heating/cooling mode, and on/off behavior, how to adjust the temperature setpoint, and how to interpret alarms such as HI/LO temperature warnings and sensor fault codes. Safety guidelines and wiring diagrams are also provided. This manual is written in Chinese.
| Working voltage | 100V‑240V 50/60Hz |
|---|---|
| Load current | 250VAC 5(3)A |
| Temperature accuracy | ±1℃ or ±1℉ |
| Room control temperature range | 5℃~30℃ (41℉~86℉) |
| Floor control temperature range | 5℃~40℃ |
| Operating environment temperature | 0℃~+50℃ |
| Storage temperature | -10℃~+60℃ |
| Dimensions | 86×86×32 mm |
Set DIP switch 1: position 1 selects Fahrenheit display, position 0 selects Celsius display. The Fahrenheit display works only in room control mode.
When the second DIP switch is set to 0, a 5‑minute compressor protection is enabled in cooling mode; the compressor will not restart until 5 minutes have passed after it stops.
This manual explains 3 error codes. Open a code for its meaning, causes and what to do: